Koheron products currently ship with firmware V0.x by default. Firmware V1 is under active development and is not publicly available yet.
Contact us if you would like early access or want to evaluate V1 firmware on your device.
profiler
Read recent MCU task-timing measurements.
The response is a table for the most recently completed 1 s measurement window. calls/s is the number of times a task ran in that window, and max_us is its longest measured execution time in microseconds. Only tasks that ran in the window are listed. The final loop row reports main-loop iterations per second and the longest measured interval between loop iterations.
Usage
>> profiler
task calls/s max_us
tec 250 103
cli_cmd 42 28
loop 1840 712
Notes
Use profiler to investigate task execution timing while the device is operating. The task names depend on the connected product and may include only tasks that ran during the previous measurement window. It is a diagnostic measurement, not a real-time safety indicator.