BUS_OVERVOLTAGE
BUS_OVERVOLTAGE error in Koheron V1 firmware.
Firmware V1 documentation ยท V1.0-rc54-2d701ce
Koheron products currently ship with firmware V0.x by default. Firmware V1 is under active development and is not publicly available yet.
Contact us if you would like early access or want to evaluate V1 firmware on your device.
BUS_OVERVOLTAGE is a common Koheron V1 firmware error. A monitored bus voltage was above an allowed limit.
| Field | Value |
|---|---|
| Error | BUS_OVERVOLTAGE |
| Bit | 10 |
| Mask | 00000400 |
| Scope | Common |
| Raised by current firmware | Yes |
Meaning
A monitored bus voltage is above an allowed operating limit. Product behavior after this error may differ by device.
Typical causes
Supply voltage too high; incorrect supply; transient or regenerative condition on the bus.
Recommended action
Check the power supply and operating conditions. Restore the bus voltage to the allowed range before clearing the error.
Related commands
Use logerr to inspect the status snapshot associated with the last error.