OUTPUT_OVERTEMPERATURE
OUTPUT_OVERTEMPERATURE error in Koheron V1 firmware.Koheron products currently ship with firmware V0.x by default. Firmware V1 is under active development and is not publicly available yet.
Contact us if you would like early access or want to evaluate V1 firmware on your device.
OUTPUT_OVERTEMPERATURE is a common Koheron V1 firmware error. A monitored output temperature exceeded an allowed limit.
| Field | Value |
|---|---|
| Error | OUTPUT_OVERTEMPERATURE |
| Bit | 12 |
| Mask | 00001000 |
| Scope | Common |
| Raised by current firmware | Yes |
Meaning
A monitored output temperature is above an allowed operating limit. Product behavior after this error may differ by device.
Typical causes
Excessive load; insufficient cooling; high ambient temperature; operation outside the specified thermal conditions.
Recommended action
Reduce load or output power if applicable, improve cooling, and allow the output or load to return within the allowed range before clearing the error.
Related commands
Use logerr to inspect the status snapshot associated with the last error.